connector shapes lost

when some visio 2003 users open vxd visio document from internet explorer, 
they receive the following error message:

"The file was opened but some problems were encountered. Details of the 
problems were added to the log file."


Then click ok, file is open but connections shapes are lost.

There are visio 2003 clients that open documents correctly on environment.

all of them office 2003 visio version: 11.316.8132

we install visio 2003 sp3 but problem still exist, there is no problem with 
visio 2007.

Do you know any bug about this issue?



thnx

0
alpert (7)
12/7/2007 8:13:36 AM
visio 3638 articles. 1 followers. Follow

2 Replies
708 Views

Similar Articles

[PageSpeed] 14

log file

Open VDX Processing Log

Source: C:\Documents and Settings\<username>\Local Settings\Temporary 
Internet Files\OLK228\HYSVisioConfiguration932.vdx

Thu Dec 06 09:20:36 2007 Begin Session

[Warning] DataType:
Context: <VisioDocument><Masters><Master ID='2' Name='Dynamic connector'> 
Sheet.5!TxtWidth
Description: Visio could not assign the specified formula to the cell and 
has substituted an alternate formula.
Old formula: MAX(TEXTWIDTH(TheText),5*Char.Size)
New formula: 0

[Warning] DataType:
Context: <VisioDocument><Pages><Page ID='0' Name='Page-1'> Dynamic 
connector.2!BeginX
Description: Visio could not assign the specified formula to the cell and 
has substituted an alternate formula.
Old formula: PAR(PNT(Process!Connections.X2,Process!Connections.Y2))
New formula: 0

[Warning] DataType:
Context: <VisioDocument><Pages><Page ID='0' Name='Page-1'> Dynamic 
connector.2!BeginY
Description: Visio could not assign the specified formula to the cell and 
has substituted an alternate formula.
Old formula: PAR(PNT(Process!Connections.X2,Process!Connections.Y2))
New formula: 0

[Warning] DataType:
Context: <VisioDocument><Pages><Page ID='0' Name='Page-1'> Dynamic 
connector.2!EndX
Description: Visio could not assign the specified formula to the cell and 
has substituted an alternate formula.
Old formula: PAR(PNT(Process.3!Connections.X1,Process.3!Connections.Y1))
New formula: 0

[Warning] DataType:
Context: <VisioDocument><Pages><Page ID='0' Name='Page-1'> Dynamic 
connector.2!EndY
Description: Visio could not assign the specified formula to the cell and 
has substituted an alternate formula.
Old formula: PAR(PNT(Process.3!Connections.X1,Process.3!Connections.Y1))
New formula: 0

[Warning] DataType:
Context: <VisioDocument><Pages><Page ID='0' Name='Page-1'> Dynamic 
connector.5!BeginX
Description: Visio could not assign the specified formula to the cell and 
has substituted an alternate formula.
Old formula: PAR(PNT(Process!Connections.X2,Process!Connections.Y2))
New formula: 0

[Warning] DataType:
Context: <VisioDocument><Pages><Page ID='0' Name='Page-1'> Dynamic 
connector.5!BeginY
Description: Visio could not assign the specified formula to the cell and 
has substituted an alternate formula.
Old formula: PAR(PNT(Process!Connections.X2,Process!Connections.Y2))
New formula: 0

[Warning] DataType:
Context: <VisioDocument><Pages><Page ID='0' Name='Page-1'> Dynamic 
connector.5!EndX
Description: Visio could not assign the specified formula to the cell and 
has substituted an alternate formula.
Old formula: PAR(PNT(Process.4!Connections.X1,Process.4!Connections.Y1))
New formula: 0

[Warning] DataType:
Context: <VisioDocument><Pages><Page ID='0' Name='Page-1'> Dynamic 
connector.5!EndY
Description: Visio could not assign the specified formula to the cell and 
has substituted an alternate formula.
Old formula: PAR(PNT(Process.4!Connections.X1,Process.4!Connections.Y1))
New formula: 0

[Warning] DataType:
Context: <VisioDocument><Pages><Page ID='0' Name='Page-1'> Dynamic 
connector.7!BeginX
Description: Visio could not assign the specified formula to the cell and 
has substituted an alternate formula.
Old formula: PAR(PNT(Process!Connections.X2,Process!Connections.Y2))
New formula: 0

[Warning] DataType:
Context: <VisioDocument><Pages><Page ID='0' Name='Page-1'> Dynamic 
connector.7!BeginY
Description: Visio could not assign the specified formula to the cell and 
has substituted an alternate formula.
Old formula: PAR(PNT(Process!Connections.X2,Process!Connections.Y2))
New formula: 0

[Warning] DataType:
Context: <VisioDocument><Pages><Page ID='0' Name='Page-1'> Dynamic 
connector.7!EndX
Description: Visio could not assign the specified formula to the cell and 
has substituted an alternate formula.
Old formula: PAR(PNT(Process.6!Connections.X1,Process.6!Connections.Y1))
New formula: 0

[Warning] DataType:
Context: <VisioDocument><Pages><Page ID='0' Name='Page-1'> Dynamic 
connector.7!EndY
Description: Visio could not assign the specified formula to the cell and 
has substituted an alternate formula.
Old formula: PAR(PNT(Process.6!Connections.X1,Process.6!Connections.Y1))
New formula: 0

[Warning] DataType:
Context: <VisioDocument><Pages><Page ID='0' Name='Page-1'> Dynamic 
connector.9!BeginX
Description: Visio could not assign the specified formula to the cell and 
has substituted an alternate formula.
Old formula: PAR(PNT(Process!Connections.X2,Process!Connections.Y2))
New formula: 0

[Warning] DataType:
Context: <VisioDocument><Pages><Page ID='0' Name='Page-1'> Dynamic 
connector.9!BeginY
Description: Visio could not assign the specified formula to the cell and 
has substituted an alternate formula.
Old formula: PAR(PNT(Process!Connections.X2,Process!Connections.Y2))
New formula: 0

[Warning] DataType:
Context: <VisioDocument><Pages><Page ID='0' Name='Page-1'> Dynamic 
connector.9!EndX
Description: Visio could not assign the specified formula to the cell and 
has substituted an alternate formula.
Old formula: PAR(PNT(Process.8!Connections.X1,Process.8!Connections.Y1))
New formula: 0

[Warning] DataType:
Context: <VisioDocument><Pages><Page ID='0' Name='Page-1'> Dynamic 
connector.9!EndY
Description: Visio could not assign the specified formula to the cell and 
has substituted an alternate formula.
Old formula: PAR(PNT(Process.8!Connections.X1,Process.8!Connections.Y1))
New formula: 0

[Warning] DataType:
Context: <VisioDocument><Pages><Page ID='0' Name='Page-1'> Dynamic 
connector.11!BeginX
Description: Visio could not assign the specified formula to the cell and 
has substituted an alternate formula.
Old formula: PAR(PNT(Process!Connections.X2,Process!Connections.Y2))
New formula: 0

[Warning] DataType:
Context: <VisioDocument><Pages><Page ID='0' Name='Page-1'> Dynamic 
connector.11!BeginY
Description: Visio could not assign the specified formula to the cell and 
has substituted an alternate formula.
Old formula: PAR(PNT(Process!Connections.X2,Process!Connections.Y2))
New formula: 0

[Warning] DataType:
Context: <VisioDocument><Pages><Page ID='0' Name='Page-1'> Dynamic 
connector.11!EndX
Description: Visio could not assign the specified formula to the cell and 
has substituted an alternate formula.
Old formula: PAR(PNT(Process.10!Connections.X1,Process.10!Connections.Y1))
New formula: 0

[Warning] DataType:
Context: <VisioDocument><Pages><Page ID='0' Name='Page-1'> Dynamic 
connector.11!EndY
Description: Visio could not assign the specified formula to the cell and 
has substituted an alternate formula.
Old formula: PAR(PNT(Process.10!Connections.X1,Process.10!Connections.Y1))
New formula: 0

[Warning] DataType:
Context: <VisioDocument><Pages><Page ID='0' Name='Page-1'> Dynamic 
connector.13!BeginX
Description: Visio could not assign the specified formula to the cell and 
has substituted an alternate formula.
Old formula: PAR(PNT(Process!Connections.X2,Process!Connections.Y2))
New formula: 0

[Warning] DataType:
Context: <VisioDocument><Pages><Page ID='0' Name='Page-1'> Dynamic 
connector.13!BeginY
Description: Visio could not assign the specified formula to the cell and 
has substituted an alternate formula.
Old formula: PAR(PNT(Process!Connections.X2,Process!Connections.Y2))
New formula: 0

[Warning] DataType:
Context: <VisioDocument><Pages><Page ID='0' Name='Page-1'> Dynamic 
connector.13!EndX
Description: Visio could not assign the specified formula to the cell and 
has substituted an alternate formula.
Old formula: PAR(PNT(Process.12!Connections.X1,Process.12!Connections.Y1))
New formula: 0

[Warning] DataType:
Context: <VisioDocument><Pages><Page ID='0' Name='Page-1'> Dynamic 
connector.13!EndY
Description: Visio could not assign the specified formula to the cell and 
has substituted an alternate formula.
Old formula: PAR(PNT(Process.12!Connections.X1,Process.12!Connections.Y1))
New formula: 0



Thu Dec 06 09:20:37 2007 End Session


Open VDX Processing Log

Source: C:\Documents and Settings\<username>\Local Settings\Temporary 
Internet Files\OLK228\HYSVisioConfiguration483.vdx

Tue Dec 04 12:09:08 2007 Begin Session

[Warning] DataType:
Context: <VisioDocument><Masters><Master ID='2' Name='Dynamic connector'> 
Sheet.5!TxtWidth
Description: Visio could not assign the specified formula to the cell and 
has substituted an alternate formula.
Old formula: MAX(TEXTWIDTH(TheText),5*Char.Size)
New formula: 0

[Warning] DataType:
Context: <VisioDocument><Pages><Page ID='0' Name='Page-1'> Dynamic 
connector.2!BeginX
Description: Visio could not assign the specified formula to the cell and 
has substituted an alternate formula.
Old formula: PAR(PNT(Process!Connections.X2,Process!Connections.Y2))
New formula: 0

[Warning] DataType:
Context: <VisioDocument><Pages><Page ID='0' Name='Page-1'> Dynamic 
connector.2!BeginY
Description: Visio could not assign the specified formula to the cell and 
has substituted an alternate formula.
Old formula: PAR(PNT(Process!Connections.X2,Process!Connections.Y2))
New formula: 0

[Warning] DataType:
Context: <VisioDocument><Pages><Page ID='0' Name='Page-1'> Dynamic 
connector.2!EndX
Description: Visio could not assign the specified formula to the cell and 
has substituted an alternate formula.
Old formula: PAR(PNT(Process.3!Connections.X1,Process.3!Connections.Y1))
New formula: 0

[Warning] DataType:
Context: <VisioDocument><Pages><Page ID='0' Name='Page-1'> Dynamic 
connector.2!EndY
Description: Visio could not assign the specified formula to the cell and 
has substituted an alternate formula.
Old formula: PAR(PNT(Process.3!Connections.X1,Process.3!Connections.Y1))
New formula: 0

[Warning] DataType:
Context: <VisioDocument><Pages><Page ID='0' Name='Page-1'> Dynamic 
connector.53!BeginX
Description: Visio could not assign the specified formula to the cell and 
has substituted an alternate formula.
Old formula: PAR(PNT(Process!Connections.X2,Process!Connections.Y2))
New formula: 0

[Warning] DataType:
Context: <VisioDocument><Pages><Page ID='0' Name='Page-1'> Dynamic 
connector.53!BeginY
Description: Visio could not assign the specified formula to the cell and 
has substituted an alternate formula.
Old formula: PAR(PNT(Process!Connections.X2,Process!Connections.Y2))
New formula: 0

[Warning] DataType:
Context: <VisioDocument><Pages><Page ID='0' Name='Page-1'> Dynamic 
connector.53!EndX
Description: Visio could not assign the specified formula to the cell and 
has substituted an alternate formula.
Old formula: PAR(PNT(Process.52!Connections.X1,Process.52!Connections.Y1))
New formula: 0

[Warning] DataType:
Context: <VisioDocument><Pages><Page ID='0' Name='Page-1'> Dynamic 
connector.53!EndY
Description: Visio could not assign the specified formula to the cell and 
has substituted an alternate formula.
Old formula: PAR(PNT(Process.52!Connections.X1,Process.52!Connections.Y1))
New formula: 0

[Warning] DataType:
Context: <VisioDocument><Pages><Page ID='0' Name='Page-1'> Dynamic 
connector.55!BeginX
Description: Visio could not assign the specified formula to the cell and 
has substituted an alternate formula.
Old formula: PAR(PNT(Process!Connections.X2,Process!Connections.Y2))
New formula: 0

[Warning] DataType:
Context: <VisioDocument><Pages><Page ID='0' Name='Page-1'> Dynamic 
connector.55!BeginY
Description: Visio could not assign the specified formula to the cell and 
has substituted an alternate formula.
Old formula: PAR(PNT(Process!Connections.X2,Process!Connections.Y2))
New formula: 0

[Warning] DataType:
Context: <VisioDocument><Pages><Page ID='0' Name='Page-1'> Dynamic 
connector.55!EndX
Description: Visio could not assign the specified formula to the cell and 
has substituted an alternate formula.
Old formula: PAR(PNT(Process.54!Connections.X1,Process.54!Connections.Y1))
New formula: 0

[Warning] DataType:
Context: <VisioDocument><Pages><Page ID='0' Name='Page-1'> Dynamic 
connector.55!EndY
Description: Visio could not assign the specified formula to the cell and 
has substituted an alternate formula.
Old formula: PAR(PNT(Process.54!Connections.X1,Process.54!Connections.Y1))
New formula: 0

[Warning] DataType:
Context: <VisioDocument><Pages><Page ID='0' Name='Page-1'> Dynamic 
connector.57!BeginX
Description: Visio could not assign the specified formula to the cell and 
has substituted an alternate formula.
Old formula: PAR(PNT(Process!Connections.X2,Process!Connections.Y2))
New formula: 0

[Warning] DataType:
Context: <VisioDocument><Pages><Page ID='0' Name='Page-1'> Dynamic 
connector.57!BeginY
Description: Visio could not assign the specified formula to the cell and 
has substituted an alternate formula.
Old formula: PAR(PNT(Process!Connections.X2,Process!Connections.Y2))
New formula: 0

[Warning] DataType:
Context: <VisioDocument><Pages><Page ID='0' Name='Page-1'> Dynamic 
connector.57!EndX
Description: Visio could not assign the specified formula to the cell and 
has substituted an alternate formula.
Old formula: PAR(PNT(Process.56!Connections.X1,Process.56!Connections.Y1))
New formula: 0

[Warning] DataType:
Context: <VisioDocument><Pages><Page ID='0' Name='Page-1'> Dynamic 
connector.57!EndY
Description: Visio could not assign the specified formula to the cell and 
has substituted an alternate formula.
Old formula: PAR(PNT(Process.56!Connections.X1,Process.56!Connections.Y1))
New formula: 0

[Warning] DataType:
Context: <VisioDocument><Pages><Page ID='0' Name='Page-1'> Dynamic 
connector.59!BeginX
Description: Visio could not assign the specified formula to the cell and 
has substituted an alternate formula.
Old formula: PAR(PNT(Process!Connections.X2,Process!Connections.Y2))
New formula: 0

[Warning] DataType:
Context: <VisioDocument><Pages><Page ID='0' Name='Page-1'> Dynamic 
connector.59!BeginY
Description: Visio could not assign the specified formula to the cell and 
has substituted an alternate formula.
Old formula: PAR(PNT(Process!Connections.X2,Process!Connections.Y2))
New formula: 0

[Warning] DataType:
Context: <VisioDocument><Pages><Page ID='0' Name='Page-1'> Dynamic 
connector.59!EndX
Description: Visio could not assign the specified formula to the cell and 
has substituted an alternate formula.
Old formula: PAR(PNT(Process.58!Connections.X1,Process.58!Connections.Y1))
New formula: 0

[Warning] DataType:
Context: <VisioDocument><Pages><Page ID='0' Name='Page-1'> Dynamic 
connector.59!EndY
Description: Visio could not assign the specified formula to the cell and 
has substituted an alternate formula.
Old formula: PAR(PNT(Process.58!Connections.X1,Process.58!Connections.Y1))
New formula: 0

[Warning] DataType:
Context: <VisioDocument><Pages><Page ID='0' Name='Page-1'> Dynamic 
connector.61!BeginX
Description: Visio could not assign the specified formula to the cell and 
has substituted an alternate formula.
Old formula: PAR(PNT(Process!Connections.X2,Process!Connections.Y2))
New formula: 0

[Warning] DataType:
Context: <VisioDocument><Pages><Page ID='0' Name='Page-1'> Dynamic 
connector.61!BeginY
Description: Visio could not assign the specified formula to the cell and 
has substituted an alternate formula.
Old formula: PAR(PNT(Process!Connections.X2,Process!Connections.Y2))
New formula: 0

[Warning] DataType:
Context: <VisioDocument><Pages><Page ID='0' Name='Page-1'> Dynamic 
connector.61!EndX
Description: Visio could not assign the specified formula to the cell and 
has substituted an alternate formula.
Old formula: PAR(PNT(Process.60!Connections.X1,Process.60!Connections.Y1))
New formula: 0

[Warning] DataType:
Context: <VisioDocument><Pages><Page ID='0' Name='Page-1'> Dynamic 
connector.61!EndY
Description: Visio could not assign the specified formula to the cell and 
has substituted an alternate formula.
Old formula: PAR(PNT(Process.60!Connections.X1,Process.60!Connections.Y1))
New formula: 0

[Warning] DataType:
Context: <VisioDocument><Pages><Page ID='0' Name='Page-1'> Dynamic 
connector.63!BeginX
Description: Visio could not assign the specified formula to the cell and 
has substituted an alternate formula.
Old formula: PAR(PNT(Process!Connections.X2,Process!Connections.Y2))
New formula: 0

[Warning] DataType:
Context: <VisioDocument><Pages><Page ID='0' Name='Page-1'> Dynamic 
connector.63!BeginY
Description: Visio could not assign the specified formula to the cell and 
has substituted an alternate formula.
Old formula: PAR(PNT(Process!Connections.X2,Process!Connections.Y2))
New formula: 0

[Warning] DataType:
Context: <VisioDocument><Pages><Page ID='0' Name='Page-1'> Dynamic 
connector.63!EndX
Description: Visio could not assign the specified formula to the cell and 
has substituted an alternate formula.
Old formula: PAR(PNT(Process.62!Connections.X1,Process.62!Connections.Y1))
New formula: 0

[Warning] DataType:
Context: <VisioDocument><Pages><Page ID='0' Name='Page-1'> Dynamic 
connector.63!EndY
Description: Visio could not assign the specified formula to the cell and 
has substituted an alternate formula.
Old formula: PAR(PNT(Process.62!Connections.X1,Process.62!Connections.Y1))
New formula: 0

[Warning] DataType:
Context: <VisioDocument><Pages><Page ID='0' Name='Page-1'> Dynamic 
connector.65!BeginX
Description: Visio could not assign the specified formula to the cell and 
has substituted an alternate formula.
Old formula: PAR(PNT(Process!Connections.X2,Process!Connections.Y2))
New formula: 0

[Warning] DataType:
Context: <VisioDocument><Pages><Page ID='0' Name='Page-1'> Dynamic 
connector.65!BeginY
Description: Visio could not assign the specified formula to the cell and 
has substituted an alternate formula.
Old formula: PAR(PNT(Process!Connections.X2,Process!Connections.Y2))
New formula: 0

[Warning] DataType:
Context: <VisioDocument><Pages><Page ID='0' Name='Page-1'> Dynamic 
connector.65!EndX
Description: Visio could not assign the specified formula to the cell and 
has substituted an alternate formula.
Old formula: PAR(PNT(Process.64!Connections.X1,Process.64!Connections.Y1))
New formula: 0

[Warning] DataType:
Context: <VisioDocument><Pages><Page ID='0' Name='Page-1'> Dynamic 
connector.65!EndY
Description: Visio could not assign the specified formula to the cell and 
has substituted an alternate formula.
Old formula: PAR(PNT(Process.64!Connections.X1,Process.64!Connections.Y1))
New formula: 0

[Warning] DataType:
Context: <VisioDocument><Pages><Page ID='0' Name='Page-1'> Dynamic 
connector.67!BeginX
Description: Visio could not assign the specified formula to the cell and 
has substituted an alternate formula.
Old formula: PAR(PNT(Process!Connections.X2,Process!Connections.Y2))
New formula: 0

[Warning] DataType:
Context: <VisioDocument><Pages><Page ID='0' Name='Page-1'> Dynamic 
connector.67!BeginY
Description: Visio could not assign the specified formula to the cell and 
has substituted an alternate formula.
Old formula: PAR(PNT(Process!Connections.X2,Process!Connections.Y2))
New formula: 0

[Warning] DataType:
Context: <VisioDocument><Pages><Page ID='0' Name='Page-1'> Dynamic 
connector.67!EndX
Description: Visio could not assign the specified formula to the cell and 
has substituted an alternate formula.
Old formula: PAR(PNT(Process.66!Connections.X1,Process.66!Connections.Y1))
New formula: 0

[Warning] DataType:
Context: <VisioDocument><Pages><Page ID='0' Name='Page-1'> Dynamic 
connector.67!EndY
Description: Visio could not assign the specified formula to the cell and 
has substituted an alternate formula.
Old formula: PAR(PNT(Process.66!Connections.X1,Process.66!Connections.Y1))
New formula: 0

[Warning] DataType:
Context: <VisioDocument><Pages><Page ID='0' Name='Page-1'> Dynamic 
connector.69!BeginX
Description: Visio could not assign the specified formula to the cell and 
has substituted an alternate formula.
Old formula: PAR(PNT(Process!Connections.X2,Process!Connections.Y2))
New formula: 0

[Warning] DataType:
Context: <VisioDocument><Pages><Page ID='0' Name='Page-1'> Dynamic 
connector.69!BeginY
Description: Visio could not assign the specified formula to the cell and 
has substituted an alternate formula.
Old formula: PAR(PNT(Process!Connections.X2,Process!Connections.Y2))
New formula: 0

[Warning] DataType:
Context: <VisioDocument><Pages><Page ID='0' Name='Page-1'> Dynamic 
connector.69!EndX
Description: Visio could not assign the specified formula to the cell and 
has substituted an alternate formula.
Old formula: PAR(PNT(Process.68!Connections.X1,Process.68!Connections.Y1))
New formula: 0

[Warning] DataType:
Context: <VisioDocument><Pages><Page ID='0' Name='Page-1'> Dynamic 
connector.69!EndY
Description: Visio could not assign the specified formula to the cell and 
has substituted an alternate formula.
Old formula: PAR(PNT(Process.68!Connections.X1,Process.68!Connections.Y1))
New formula: 0

[Warning] DataType:
Context: <VisioDocument><Pages><Page ID='0' Name='Page-1'> Dynamic 
connector.71!BeginX
Description: Visio could not assign the specified formula to the cell and 
has substituted an alternate formula.
Old formula: PAR(PNT(Process!Connections.X2,Process!Connections.Y2))
New formula: 0

[Warning] DataType:
Context: <VisioDocument><Pages><Page ID='0' Name='Page-1'> Dynamic 
connector.71!BeginY
Description: Visio could not assign the specified formula to the cell and 
has substituted an alternate formula.
Old formula: PAR(PNT(Process!Connections.X2,Process!Connections.Y2))
New formula: 0

[Warning] DataType:
Context: <VisioDocument><Pages><Page ID='0' Name='Page-1'> Dynamic 
connector.71!EndX
Description: Visio could not assign the specified formula to the cell and 
has substituted an alternate formula.
Old formula: PAR(PNT(Process.70!Connections.X1,Process.70!Connections.Y1))
New formula: 0

[Warning] DataType:
Context: <VisioDocument><Pages><Page ID='0' Name='Page-1'> Dynamic 
connector.71!EndY
Description: Visio could not assign the specified formula to the cell and 
has substituted an alternate formula.
Old formula: PAR(PNT(Process.70!Connections.X1,Process.70!Connections.Y1))
New formula: 0

[Warning] DataType:
Context: <VisioDocument><Pages><Page ID='0' Name='Page-1'> Dynamic 
connector.73!BeginX
Description: Visio could not assign the specified formula to the cell and 
has substituted an alternate formula.
Old formula: PAR(PNT(Process!Connections.X2,Process!Connections.Y2))
New formula: 0

[Warning] DataType:
Context: <VisioDocument><Pages><Page ID='0' Name='Page-1'> Dynamic 
connector.73!BeginY
Description: Visio could not assign the specified formula to the cell and 
has substituted an alternate formula.
Old formula: PAR(PNT(Process!Connections.X2,Process!Connections.Y2))
New formula: 0

[Warning] DataType:
Context: <VisioDocument><Pages><Page ID='0' Name='Page-1'> Dynamic 
connector.73!EndX
Description: Visio could not assign the specified formula to the cell and 
has substituted an alternate formula.
Old formula: PAR(PNT(Process.72!Connections.X1,Process.72!Connections.Y1))
New formula: 0

[Warning] DataType:
Context: <VisioDocument><Pages><Page ID='0' Name='Page-1'> Dynamic 
connector.73!EndY
Description: Visio could not assign the specified formula to the cell and 
has substituted an alternate formula.
Old formula: PAR(PNT(Process.72!Connections.X1,Process.72!Connections.Y1))
New formula: 0

[Warning] DataType:
Context: <VisioDocument><Pages><Page ID='0' Name='Page-1'> Dynamic 
connector.75!BeginX
Description: Visio could not assign the specified formula to the cell and 
has substituted an alternate formula.
Old formula: PAR(PNT(Process!Connections.X2,Process!Connections.Y2))
New formula: 0

[Warning] DataType:
Context: <VisioDocument><Pages><Page ID='0' Name='Page-1'> Dynamic 
connector.75!BeginY
Description: Visio could not assign the specified formula to the cell and 
has substituted an alternate formula.
Old formula: PAR(PNT(Process!Connections.X2,Process!Connections.Y2))
New formula: 0

[Warning] DataType:
Context: <VisioDocument><Pages><Page ID='0' Name='Page-1'> Dynamic 
connector.75!EndX
Description: Visio could not assign the specified formula to the cell and 
has substituted an alternate formula.
Old formula: PAR(PNT(Process.74!Connections.X1,Process.74!Connections.Y1))
New formula: 0

[Warning] DataType:
Context: <VisioDocument><Pages><Page ID='0' Name='Page-1'> Dynamic 
connector.75!EndY
Description: Visio could not assign the specified formula to the cell and 
has substituted an alternate formula.
Old formula: PAR(PNT(Process.74!Connections.X1,Process.74!Connections.Y1))
New formula: 0

[Warning] DataType:
Context: <VisioDocument><Pages><Page ID='0' Name='Page-1'> Dynamic 
connector.77!BeginX
Description: Visio could not assign the specified formula to the cell and 
has substituted an alternate formula.
Old formula: PAR(PNT(Process!Connections.X2,Process!Connections.Y2))
New formula: 0

[Warning] DataType:
Context: <VisioDocument><Pages><Page ID='0' Name='Page-1'> Dynamic 
connector.77!BeginY
Description: Visio could not assign the specified formula to the cell and 
has substituted an alternate formula.
Old formula: PAR(PNT(Process!Connections.X2,Process!Connections.Y2))
New formula: 0

[Warning] DataType:
Context: <VisioDocument><Pages><Page ID='0' Name='Page-1'> Dynamic 
connector.77!EndX
Description: Visio could not assign the specified formula to the cell and 
has substituted an alternate formula.
Old formula: PAR(PNT(Process.76!Connections.X1,Process.76!Connections.Y1))
New formula: 0

[Warning] DataType:
Context: <VisioDocument><Pages><Page ID='0' Name='Page-1'> Dynamic 
connector.77!EndY
Description: Visio could not assign the specified formula to the cell and 
has substituted an alternate formula.
Old formula: PAR(PNT(Process.76!Connections.X1,Process.76!Connections.Y1))
New formula: 0

[Warning] DataType:
Context: <VisioDocument><Pages><Page ID='0' Name='Page-1'> Dynamic 
connector.79!BeginX
Description: Visio could not assign the specified formula to the cell and 
has substituted an alternate formula.
Old formula: PAR(PNT(Process!Connections.X2,Process!Connections.Y2))
New formula: 0

[Warning] DataType:
Context: <VisioDocument><Pages><Page ID='0' Name='Page-1'> Dynamic 
connector.79!BeginY
Description: Visio could not assign the specified formula to the cell and 
has substituted an alternate formula.
Old formula: PAR(PNT(Process!Connections.X2,Process!Connections.Y2))
New formula: 0

[Warning] DataType:
Context: <VisioDocument><Pages><Page ID='0' Name='Page-1'> Dynamic 
connector.79!EndX
Description: Visio could not assign the specified formula to the cell and 
has substituted an alternate formula.
Old formula: PAR(PNT(Process.78!Connections.X1,Process.78!Connections.Y1))
New formula: 0

[Warning] DataType:
Context: <VisioDocument><Pages><Page ID='0' Name='Page-1'> Dynamic 
connector.79!EndY
Description: Visio could not assign the specified formula to the cell and 
has substituted an alternate formula.
Old formula: PAR(PNT(Process.78!Connections.X1,Process.78!Connections.Y1))
New formula: 0

[Warning] DataType:
Context: <VisioDocument><Pages><Page ID='0' Name='Page-1'> Dynamic 
connector.81!BeginX
Description: Visio could not assign the specified formula to the cell and 
has substituted an alternate formula.
Old formula: PAR(PNT(Process!Connections.X2,Process!Connections.Y2))
New formula: 0

[Warning] DataType:
Context: <VisioDocument><Pages><Page ID='0' Name='Page-1'> Dynamic 
connector.81!BeginY
Description: Visio could not assign the specified formula to the cell and 
has substituted an alternate formula.
Old formula: PAR(PNT(Process!Connections.X2,Process!Connections.Y2))
New formula: 0

[Warning] DataType:
Context: <VisioDocument><Pages><Page ID='0' Name='Page-1'> Dynamic 
connector.81!EndX
Description: Visio could not assign the specified formula to the cell and 
has substituted an alternate formula.
Old formula: PAR(PNT(Process.80!Connections.X1,Process.80!Connections.Y1))
New formula: 0

[Warning] DataType:
Context: <VisioDocument><Pages><Page ID='0' Name='Page-1'> Dynamic 
connector.81!EndY
Description: Visio could not assign the specified formula to the cell and 
has substituted an alternate formula.
Old formula: PAR(PNT(Process.80!Connections.X1,Process.80!Connections.Y1))
New formula: 0

[Warning] DataType:
Context: <VisioDocument><Pages><Page ID='0' Name='Page-1'> Dynamic 
connector.83!BeginX
Description: Visio could not assign the specified formula to the cell and 
has substituted an alternate formula.
Old formula: PAR(PNT(Process!Connections.X2,Process!Connections.Y2))
New formula: 0

[Warning] DataType:
Context: <VisioDocument><Pages><Page ID='0' Name='Page-1'> Dynamic 
connector.83!BeginY
Description: Visio could not assign the specified formula to the cell and 
has substituted an alternate formula.
Old formula: PAR(PNT(Process!Connections.X2,Process!Connections.Y2))
New formula: 0

[Warning] DataType:
Context: <VisioDocument><Pages><Page ID='0' Name='Page-1'> Dynamic 
connector.83!EndX
Description: Visio could not assign the specified formula to the cell and 
has substituted an alternate formula.
Old formula: PAR(PNT(Process.82!Connections.X1,Process.82!Connections.Y1))
New formula: 0

[Warning] DataType:
Context: <VisioDocument><Pages><Page ID='0' Name='Page-1'> Dynamic 
connector.83!EndY
Description: Visio could not assign the specified formula to the cell and 
has substituted an alternate formula.
Old formula: PAR(PNT(Process.82!Connections.X1,Process.82!Connections.Y1))
New formula: 0

[Warning] DataType:
Context: <VisioDocument><Pages><Page ID='0' Name='Page-1'> Dynamic 
connector.85!BeginX
Description: Visio could not assign the specified formula to the cell and 
has substituted an alternate formula.
Old

"The NomaD" <alpert@online-msdestek.com> wrote in message 
news:O2FoSkKOIHA.5264@TK2MSFTNGP02.phx.gbl...
> when some visio 2003 users open vxd visio document from internet explorer, 
> they receive the following error message:
>
> "The file was opened but some problems were encountered. Details of the 
> problems were added to the log file."
>
>
> Then click ok, file is open but connections shapes are lost.
>
> There are visio 2003 clients that open documents correctly on environment.
>
> all of them office 2003 visio version: 11.316.8132
>
> we install visio 2003 sp3 but problem still exist, there is no problem 
> with visio 2007.
>
> Do you know any bug about this issue?
>
>
>
> thnx
> 

0
alpert (7)
12/7/2007 8:16:49 AM
Did you edit the vxd file using Visio 2003, Visio 2007 or a text editor.

From the log it appears that it can not resolve some references and the 
formulas are replaced by "0".  This also appears as a cascading problem. One 
cell is replaced by "0" makes another cell fail, which makes another cell 
fail. etc.

John...    Visio MVP

Need stencils or ideas? http://visio.mvps.org/3rdparty.htm
Need VBA examples?   http://visio.mvps.org/VBA.htm
Visio Wishlist       http://visio.mvps.org/wish_list.htm
"The NomaD" <alpert@online-msdestek.com> wrote in message 
news:O2FoSkKOIHA.5264@TK2MSFTNGP02.phx.gbl...
> when some visio 2003 users open vxd visio document from internet explorer, 
> they receive the following error message:
>
> "The file was opened but some problems were encountered. Details of the 
> problems were added to the log file."
>
>
> Then click ok, file is open but connections shapes are lost.
>
> There are visio 2003 clients that open documents correctly on environment.
>
> all of them office 2003 visio version: 11.316.8132
>
> we install visio 2003 sp3 but problem still exist, there is no problem 
> with visio 2007.
>
> Do you know any bug about this issue?
>
>
>
> thnx
> 


0
lancucki (505)
12/7/2007 12:06:09 PM
Reply:

Similar Artilces:

Pop3 Connector
Somebody knows how can I get the results of pop3 connector for Small Business in the exchange 2000 server? I want to get messages from external ISP and distribute for internal exchange accounts. http://support.microsoft.com/default.aspx?scid=kb;en-us;306802 http://www.swinc.com/resource/exch_smtp_diatribe.htm Alexandre wrote: > Somebody knows how can I get the results of pop3 connector for Small Business in the exchange 2000 server? > I want to get messages from external ISP and distribute for internal exchange accounts. ...

Outlook Connector what is the latest version?
I've been trying to install Outlook Connector 12.1. I've been having problems installing, when I do a Outlook Connector/About Outlook Connector the version reported is Microsoft® Office Outlook® Connector ( 12.0.6414.1000 ) is that 12.1? MonroeCheeseman, you wrote on Wed, 21 Jan 2009 06:30:01 -0800: > I've been trying to install Outlook Connector 12.1. I've been having > problems installing, when I do a Outlook Connector/About Outlook Connector > the version reported is > > Microsoft� Office Outlook� Connector ( 12.0.6414.1000 ) > &g...

losts of questions
WHY DO WE CONTINUE WITH MICROSOFT? E.G. THIS SERVICE WEBSIDE , IT IS USELESS. HUNDREDS AND HUNDREDS OF QUESTIONS BUT NO ANSWERES In article <034701c3c036$0db664d0$a501280a@phx.gbl>, anonymous@discussions.microsoft.com says... |WHY DO WE CONTINUE WITH MICROSOFT? E.G. THIS SERVICE |WEBSIDE , IT IS USELESS. HUNDREDS AND HUNDREDS OF |QUESTIONS BUT NO ANSWERES | Oh dear. Click on the "+" sign to see the hundreds of replies to the hundreds of questions. Or, use a PROPER newsreader. ...

Lost System Information
Hi, I have xp pro sp2 and for reasons unknown I cannot use system info link. When I access it I have box open with words Cant Collect information, and more stating Cannot access Windows Management instrumentation software, Windows Management files may be moved or missing ! I have run Disc Check fully and defrag without any change. My PC appears to operate as normal, but can you assist with problem please. Roger ------------------------------------------------------ ------------------------------------------------------ Roger wrote: > Hi, > I have xp p...

Romve Third Party Connector from Exchange 5.5
Hi everyone, My platform is Win NT4 SP6 and exchange 5.5 SP4. Can anyone please let me know the procedure to remove GoldFax connector from exchange because I am getting replication errors with the eventid 2037. Thanks in advance. You probably need to remove the extensions from your recipient container(s) in Exchange Admin raw mode unless the applicaiton has an uninstall routine. I strongly recommend contacting the vendor directly for instructions on how to do this. Hacking the product out of Exchange could leave your organization in a non-operational state and would likely require a...

Connectors...
Is there any way to manually remove connectors? I originally migrated from Novell Groupwise to Exchange quite a while ago, but the following connectors remain within the System Manager and I can't figure out how to remove them: Connector for Novell Groupwise Calendar Connector Thanx. version of Exchange? "Steven Sinclair" <StevenSinclair@discussions.microsoft.com> wrote in message news:850F46A7-505D-4130-AE22-24627C6687BF@microsoft.com... > Is there any way to manually remove connectors? > > I originally migrated from Novell Groupwise to Exchange quite a whi...

Several charts in Works spreadsheet into Excel seem lost.
I have a spreadsheet that collects rainfall during the year and provides plots showing month by month and YTD against normal rain fall. When I imported this into Excel, all the charts, which were not easy to set up with various matching ranges of fields seem to have disappeared. Are they really gone? Why does Microsoft hate Works so much? ...

Legends
Hi, I've got two charts, charting ten items each. In one chart when I place the legend at the bottom it produces a wide box with two columns of five items in each column, resulting in a big space for the graph. The other chart has a legend also at the bottom, but with one column of ten items, resulting in a smaller graph. How do I manipulate the legend box to give me two columns for the items? I've tried dragging the placeholders, but it won't go into two columns. Thanks for looking. Paul Hi, Select the whole legend box and increase its width by dragging on of the sizin...

Emails shows as read message in out look after pop3 connector
Hi We configured exchange email router . Everythig is working fine. But once e-email came to Outlook, after some time email status chaged into read mode. Eventhough user dont open that message in outlook this will happen automatically after next send and receive from outlook. We used POP3 connector to read emails from echange server. This is happening to crm users only. What configuration changes can we make to remove this issue. Avance thanks forany type of help sujith Review the setting the CRM System Setting >> Outlook tab >> Perform checks as new e-mai lis received ...

CRM-GP Connector
I recently installed the CRM Connector for GP. WE have one server that is holds both GP and CRM (w/ SQL2005). Since the connector requires SQL 2000, we have a second server that has the CRM-GP Connector. When trying to run the Data Synchronization tool to sync data between CRM and GP we get the following error in the event log: Login failed for user 'NT AUTHORITY\ANONYMOUS LOGON'. Any ideas? Is there a service or component somewhere that needs credentials. On the GP/CRM Server we see the same message in the event log. Thanks in advance for any help ...

Outlook and the Lotus Notes Connector
I'm using Outlook 2003 and the latest Notes Connector. How do I access more than one Notes mailbox inside Outlook? ...

Exchange 2003
Hi Could anyone tell me if Exchange 2003 has a POP3 connector built into it? If not, could third party POP3 connectors be used with it? Thanks lewej > Could anyone tell me if Exchange 2003 has a POP3 > connector built into it? If not, could third party POP3 > connectors be used with it? Only the SMB version has a built-in pop-connector. There are several third party connectors that work fine. I've tried PopBeamer and GFI MailEssentials with no trouble. Eirik No it doesn't but I believe the SBS version does. There are plenty of 3rd party ones available that Google will...

Do I need outlook connector for office 2010 as with outlook 2007?
I see links to download the hotmail connector for office Outlook 2007, but not for the Beta trial, which I plan to get the full version when it's available. My phone runs on Windows Mobile 6.0, and I can't sync contacts with my pc without Outlook N Pietro wrote: > I see links to download the hotmail connector for office Outlook 2007, but > not for the Beta trial, which I plan to get the full version when it's > available. My phone runs on Windows Mobile 6.0, and I can't sync contacts > with my pc without Outlook This newsgroup discusses the rel...

SMTP Connector #6
OK this is what I have. I was in the middle of an 5.5. to e2k3 migration when the 5.5. server died. In e2k3 i have a smtp connector and a internet mail service ( the one from 5.5) I cant delete or even remove it from the 2003 box and the 5.5 box is dead. How do I remove it so I can just have the smtp connector on my 2003 box? Thanks You'll need to delete it with ADSIEdit, I expect. If you're not sure about this, I'd get Microsoft PSS on the phone to help you. -- Neil Hobson Exchange MVP For Exchange news, links and tips, check: http://www.msexchangeblog.com "BOS...

Outlook Connector Not Working....
This morning Outlook 2003 with the Connector was fine. Now it fails to work. Allowed the update to download and it said it installed, but I still get the error message on startup of Outlook. Microsoft...what have you done to my Outlook? I can't download emails this evening for my business? Office Outlook 2003. Been using web-based email for several years which meant I had to employ Outlook connector when setup. This afternoon, I open Outlook to check enmail and get a pop up requiring Connnector to be upgraded. I follow promps, it goes through the install, closes the ...

No Connector?
While viewing Exchange System Manager I notice I don't have any Connectors under my only Server tree. Could this be why my clients can't connect to the server? If so, how do I add a connector? tks, steve you only need connectors if you want to specify restrictions on Internet email or you need to connect to other sites or foreign systems...what happens when your users try to open Outlook? "sjs" <sjs@discussions.microsoft.com> wrote in message news:EF8DA481-F361-4865-8191-7F5FF37246A5@microsoft.com... > While viewing Exchange System Manager I notice I don't...

shapes #3
I am trying to find a shape like a rectangle but with only one corner rounded. Can't seem to find one anywhere. Any suggestions? I know I can do that in Visio but I don't know about doing it in Publisher with Autoshapes. I know that I can copy and paste into Word from there. I assume that would also apply to Publisher. (I'm at work now and don't have Pub here.) Don't suppose you have Visio? -- JoAnn Paules MVP Microsoft [Publisher] ~~~~~ How to ask a question http://support.microsoft.com/KB/555375 "Wanna_B_A_Reiner" <WannaBAReiner@discussions.micros...

software loaded-register, lost the disks
I recently switched from ME to XP (operating systems), now it is asking for me to load the disk for several office programs. I don't have the disks anymore..... do I have to repurchase the software, or can I somehow get the componenets from my registration numbers..... ...

connector/connector crossover points
Can I set that a connector goes over/under another connector at the crossover points? If so, how? File \ Page Setup \ Layout and Routing and under the Line Jumps section, there are several options. "Jonas" <jonas@gauffin.org> wrote in message news:eg0rJ0SnDHA.2444@TK2MSFTNGP09.phx.gbl... > Can I set that a connector goes over/under another connector at the > crossover points? > If so, how? > > "RA" <asdf@microsoft.com> wrote in message news:3f9ebb1e$1@news.microsoft.com... > File \ Page Setup \ Layout and Routing and under the Line Jump...

CRM 3.0 Workflows Lost...
Hi everyone, We have a client (still on 3.0) that recently (accidentally) deleted their CRM 3.0 db Virtual Server on which we had numerous custom Sales Processes and WF rules, many of which were not backed up. They have since re-created their development environment on a new set of servers, but we only have the WF Rules and Sales Processes that were in their Production environment. The original CRM Application Development Server still exists (as well as the Workflow manager on which the "lost" workflows were created). I'm wondering if these workflows are stored anywhere...

Tectura CRM Connector
We are planning a CRM deployment. We are using Navision 3.70b and want to use the Tectura CRM connector to integrate the two systems. Does anybody have any experience with this scenario or a deployment guide for the connector. Terje I know a Navision MVP who is interested in working on this connector. If this is of interest let me know . -- Anne Stanton, MVP-CRM, MBA/ACC President The Norwich Group http://www.thenorwichgroup.com http://thenorwichgroup.blogs.com "Terje Sundboe" <tsundboe@msn.com> wrote in message news:04D4773F-B906-4ABF-ACD9-C4AD57656EF9@microsoft....

I lost manual guide book and install disk
Oh~ I'm so sad. Our company's member lost MS retail management Guide book and install CD. Guide book! it is so important for me to learn many kinds of function. So I want to buy or get guide book and install disk. How can i do that ? If i request to MS service, Can i get that? hi Judy, RMS has context sensitive help, which can be accessed by clicking help on most of the screens in RMS. You can also go to help by clicking on help - contents in Manager or F1 on POS. Regards, Mustafa Husain Retail Realm Ltd. "Judy" wrote: > Oh~ I'm so sad. > Our company's m...

Outlook Connector 12.1
I have installed Outlook Connector 12.1 (12.0.6423) in Outlook 2003. I was able to download all the email messages from my Hotmail account into Outlook, but several of them have severely truncated subject lines, while others do not. Also, several of these messages have excessive extra line breaks, even when the window states "Extra line breaks in this message were removed." I cannot find a pattern to this. The subject lines and line breaks are complete and normal when viewed via Hotmail. I tried the 'repair Outlook Connector' feature via "Control Panel...

Cisco Communications Connector
Does anyone know when if and when Cisco is going to release a communications connector for CRM 3.0? I would assume its atleast 3 months away if they are going to come out with it at all. I found it if anyone is interested. Its now called Cisco Unified CRM Connector 3.0 Client/Server You can find it after logging onto Cisco download portal and looking for the old 2.1 version. It took a day to install and seems to work pretty smoothly once configured properly. Very nice tool and since its free if you have Cisco Phones I definatly recommend it. I am having an issue with one computer....

Data within a Shape
I am using Office Visio 2007. I have encountered two issues that I need a solution on how to do it!!! Questions: (1) How do I create a shape where I want to calendar date to appear within a shape? e.g., rectangle box and the current date would appear November 17, 2006 (2) How do you make "annotation" work? e.g., callout "A" is update to be "C" everywhere in the drawing this should happen -- saXso You have two options in Visio 2007. If you want the shape text itself to display the current date, select the shape and choose Insert > Field. Then you ca...